After the injection process, the Dielectric Test Machine will help us to detect pores at the bottom of the automotive battery cases, thanks to the use of the HI-POT type test Model 19057-20, 20 KV.
MAIN FEATURES:
Fault Detection in the Injection Process
Focus on injection sites
Installation on one side of the injection machine
Boxes are tested immediately after being injected
Operator-safe Dielectric Test
Cycle time less than 30 second (2 per minute)
Approved boxes marked with a paint point
NOT Approved boxes are perforated and rejected
Statistical report on the screen, by turn or global