Bulk Air Gases Discharge Process

,

 In 2023 one of our Clients in the Gases Industry asked for a solution for their Pipe Trailers Control Panel, they wanted a system to be able to connect to different Electrical Supply Systems 220 or 440 VAC and also to be protected in case of low voltage situations. Also it was required that the system protect the pump to operate under cryogenic temperature. For this case, we designed the DGA panel that is a robust control system designed for cryogenic pump applications in Air Gases (Oxygen or Nitrogen) transfer systems. It ensures safe and efficient delivery from mobile units to stationary tanks by automating voltage detection and system protection.

Smart Adaptability:

The system automatically detects the supply voltage (220VAC or 440VAC nominal) at each installation site and reconfigures internal motor connections accordingly—eliminating the need for manual adjustments and reducing setup time.

It also monitors:

  • Cryogenic pump temperature
  • Rotation phase sequence
  • Voltage levels and overcurrent conditions

Operational Guidance & Safety:

Visual indicators notify the operator when all conditions are correct to begin the transfer process. Continuous monitoring ensures the equipment stays within safe operating parameters throughout the operation.

Key Benefits:

  • Eliminate motor problems with automatic voltage detection and motor connection adjustment
  • Integrated protection against temperature, rotation errors, overvoltage, and overcurrent
  • Sturdy aluminum plate structure with hinged access covers
  • Weather-resistant stainless steel enclosure (IP65 rated)

The DGA panel is ideal for industrial gas suppliers looking to ensure safe, mobile, and reliable gas transfer operations across diverse customer facilities.

Skills